GstarCAD Network Licence Manager does not start
In short
If client computers cannot connect to the GstarCAD Network Licence and the GstarCAD Network Licence Manager (GNLM) does not start on the server, first remove any duplicate Licence Manager installations and install the latest GNLM version. If GNLM still does not start, check its configured ports, antivirus software, firewall, and server-side network permissions.
Problem
The customer is experiencing issues with the GstarCAD Network Licence. The client computers cannot connect to the network licence server.
The licence server is running on a virtual server. A GstarCAD Network Licence Manager (GNLM) installation was found on the server, but the application could not be started.
The following steps have already been attempted without success:
- Reinstalling the Licence Manager
- Installing a newer version of the Licence Manager
- Attempting to start the Licence Manager
The issue therefore appears to be related to the server-side Licence Manager installation, configuration, or a security/port restriction.
Recommended troubleshooting
Check for multiple Licence Manager installations
Make sure that only one GstarCAD Licence Server tool is installed on the server.
First, uninstall or remove all existing GstarCAD Network Licence Manager installations and check that the following folders are no longer present:
C:\Program Files\Common Files\Gstarsoft\GNLM
C:\Program Files\Common Files\Gstarsoft\Licence service
C:\GstarCAD NerWork Licence Manager X64
Multiple installations
Having multiple versions or installations of the Licence Manager can cause conflicts.
Install the latest GNLM version
Download and install the latest GstarCAD Network Licence Manager:
After installation, run the GNLM application and start the licence server. The network licence can then be activated on the server.
If GNLM does not start
If the Licence Manager still cannot be started, check the configured communication ports.
Try changing the two ports configured in GNLM and then restart the Licence Manager.
Also verify that the selected ports are not already being used by another application or service.
Check antivirus and security software
Security software on the server may prevent GNLM from starting or may block its network communication.
Security software test
Temporarily disable antivirus or endpoint security software and the firewall as a test, then try starting GNLM again.
If GNLM starts after disabling the security software, configure an exception for the GstarCAD Network Licence Manager and its required ports instead of leaving the security software disabled.
Important
Because the licence server is running on a virtual server, the IT administrator should also verify that:
- The virtual machine has stable network connectivity.
- The server’s IP address is accessible from the client PCs.
- The GNLM service is allowed through the server firewall.
- The required licence ports are open.
- No other GNLM or Licence Manager service is running simultaneously.
Troubleshoot the server first
If the Licence Manager application itself does not start at all, resolving that server-side issue should be the first priority before troubleshooting the client-side network licence connection.